Benger J, Coates D, Davies S, Greenwood R, Nolan J, Rhys M, Thomas M, Voss S. Br J Anaesth. 2016;116(2):262-8
A cluster randomised trial of paramedics within one ambulance service in England over a 12-month period, split into groups using either the i-gel or LMA Supreme or usual practice for all patients with non-traumatic adult OHCA. Primary outcome was study feasibility, including recruitment and protocol adherence. Secondary outcomes included survival to hospital discharge and to 90 days. 184 of 535 paramedics consented, with 615 patients recruited. The LMA Supreme arm was suspended following 'adverse incidents'. No differences were reported in secondary outcomes.
Link to abstract
Tags :
2016,
Benger J,,
Br J Anaesth,
RCT,
OHCA,
Airway management,
Resuscitation,
Paramedics,
Ambulance service,
Adult,
vs LMA Supreme,
Feasability study,
Free
52041014-092a-40df-9b94-9b37e81d459a|1|1.0|27604f05-86ad-47ef-9e05-950bb762570c
Gupta B, Gupta S, Hijam B, Shende P, Rewari V. J Emerg Trauma Shock. 2015 Oct-Dec;8(4):188-92
Insertion of i-gel, ProSeal and LMA Classic were studied in prone position. Time to insertion, ease of insertion, bronchoscopic view an insertion score were compared. i-gel was the quickest and easiest to insert.
Link to abstract
Tags :
2015,
Gupta B,
J Emerg Trauma Shock,
Adult,
RCT,
Rescue,
Emergency medicine,
Manikin study,
vs ProSeal,
vs LMA,
Prone,
Resuscitation,
Free
e87e652d-e4fe-4c2b-b089-f82fb3b598ab|1|3.0|27604f05-86ad-47ef-9e05-950bb762570c
Bernhard M, Benger JR. Curr Opin Crit Care. 2015 Jun;21(3):183-7
An evaluation of latest scientific evidence regarding airway management during in- and out-of-hospital CPR.
Link to abstract
Tags :
2015,
Bernhard M,
Benger J ,
Curr Opin Crit Care,
Airway management,
OHCA,
In-hospital cardiac arrest,
in-hospital CPR,
cardiac arrest,
CPR,
Resuscitation,
vs Portex Soft Seal
bdf97a53-b514-4aa3-a606-c5c3d9a5fae7|1|3.0|27604f05-86ad-47ef-9e05-950bb762570c
Galderisi A, De Bernardo G, Lorenzon E, Trevisanuto D. BMJ Case Rep. 2015 Mar 25;2015
Successful report of an infant resuscitated at birth using a size 1 i-gel, positioned by a trainee paediatrician at first attempt, after failed face-mask ventilation.
Link to abstract
498a5412-f41d-4e05-86be-77e2fac88652|1|3.0|27604f05-86ad-47ef-9e05-950bb762570c
Kohama H, Komasawa N, Ueki R, Kaminoh Y, Nishi S. Pediatr Int. 2015;57(1):180-2
Study on performance of air-Q, Ambu Aura-i and i-gel in a manikin simulation, undertaken by 22 novice physicians. Rate of success and insertion time with and without chest compressions were measured.
Link to abstract
Tags :
2015,
Kohama H,
Pediatr Int,
Manikin study,
Paediatric,
Novice users,
Chest compressions,
Resuscitation,
Infant,
Simulation,
Comparison trial,
vs air-Q,
vs Ambu Aura-i,
Free
75068e02-bd37-4608-b5bd-dac5540f665b|1|3.0|27604f05-86ad-47ef-9e05-950bb762570c