Evaluation of the efficacy of six supraglottic devices for airway management in dark conditions: a crossover randomized simulation trial

Ohchi F, Komasawa N, Imagawa K, Okamoto K, Minami T. J Anesth. 2015 Dec;29(6):887-92

15 novice doctors and 17 with >2 years experience were asked to insert each airway device into a manikin in random order. This was done in a windowless room with all the lights on and again with the lights switched off. Insertion time, insertion success, and participant's own perception of ease of use were all recorded. Ventilation success was lower in both groups when using the ProSeal and cLMA in the dark. Insertion time for these devices was longer in the dark, an effect that was also seen in both groups. Both ProSeal and cLMA were rated as more difficult to use in the dark compared with light conditions and with other devices. These results are thought to be due to the difference in design between these airways and the others used in the study, which are stiffer and anatomically shaped.

Link to abstract

Role of laryngeal mask airway in laparoscopic cholecystectomy

Belena JM, Ochoa EJ, Nunez M, Gilsanz C, Vidal A. World J Gastrointest Surg. 2015;7(11):319-25

Literature search performed on laryngeal mask airway devices with drain tubes to determine efficacy of ventilation and protection against aspiration when compared with tracheal intubation. Results included studies on LMA Supreme, LMA Classic, LMA ProSeal and i-gel.

Link to abstract

Comparison of i-gel® and LMA Supreme® during laparoscopic cholecystectomy

Park SY, Rim JC, Kim H, Lee JH, Chung CJ. Korean J Anesthesiol. 2015 Oct;68(5):455-61

93 patients were allocated into i-gel or LMA Supreme groups, with insertion time, attempts and fibreoptic view of glottis recorded. No significant differences were recorded.

Link to abstract

Small is the new big: An overview of newer supraglottic airways for children

Goyal R. J Anaesthesiol Clin Pharmacol. 2015 Oct-Dec;31(4):440-9

Overview of currently available options in paediatric sizes, suitability of each, published data and general concerns regarding their use.

Link to abstract

Randomized comparison of the i-gel(TM) with the LMA Supreme (TM) in anesthetized adult patients

Beleña JM, Núñez M, Vidal A, Gasco C, Alcojor A, Lee P, Pérez JL. Anaesthesist. 2015 Apr;64(4):271-6

140 patients split into device groups, with speed of insertion, success rates, leak pressure and tidal volume evaluated. i-gel proved quicker to insert and generally the results were comparable.

Link to abstract.