Evaluation of the efficacy of six supraglottic devices for airway management in dark conditions: a crossover randomized simulation trial

Ohchi F, Komasawa N, Imagawa K, Okamoto K, Minami T. J Anesth. 2015 Dec;29(6):887-92

15 novice doctors and 17 with >2 years experience were asked to insert each airway device into a manikin in random order. This was done in a windowless room with all the lights on and again with the lights switched off. Insertion time, insertion success, and participant's own perception of ease of use were all recorded. Ventilation success was lower in both groups when using the ProSeal and cLMA in the dark. Insertion time for these devices was longer in the dark, an effect that was also seen in both groups. Both ProSeal and cLMA were rated as more difficult to use in the dark compared with light conditions and with other devices. These results are thought to be due to the difference in design between these airways and the others used in the study, which are stiffer and anatomically shaped.

Link to abstract

Role of laryngeal mask airway in laparoscopic cholecystectomy

Belena JM, Ochoa EJ, Nunez M, Gilsanz C, Vidal A. World J Gastrointest Surg. 2015;7(11):319-25

Literature search performed on laryngeal mask airway devices with drain tubes to determine efficacy of ventilation and protection against aspiration when compared with tracheal intubation. Results included studies on LMA Supreme, LMA Classic, LMA ProSeal and i-gel.

Link to abstract

Comparison of Four Different Supraglottic Airway Devices in Terms of Efficacy, Intra-ocular Pressure and Haemodynamic Parameters in Children Undergoing Ophthalmic Surgery

Peker G, Takmaz SA, Baltacı B, Başar H, Kotanoğlu M. Turk J Anaesthesiol Reanim. 2015 Oct;43(5):304-12

Prospective, randomised study on 60 children aged 1-10 years. Insertion attempts and ease, leak pressure and complications were recorded. Results suggest no difference between the devices under these conditions.

Link to abstract

Comparison of three supraglottic airway devices for airway rescue in the prone position: A manikin-based study

Gupta B, Gupta S, Hijam B, Shende P, Rewari V. J Emerg Trauma Shock. 2015 Oct-Dec;8(4):188-92

Insertion of i-gel, ProSeal and LMA Classic were studied in prone position. Time to insertion, ease of insertion, bronchoscopic view an insertion score were compared. i-gel was the quickest and easiest to insert.

Link to abstract

High arch palate: A bane for ProSeal laryngeal mask airway but a boon for I-gel

Bala R, Hazarika A, Pandia MP, Kumar N. J Anaesthesiol Clin Pharmacol. 2015 Oct-Dec;31(4):568

Report of failed ProSeal insertion, with i-gel successfully inserted in its place at the first attempt.