The use of the i-gel® in a developing country

Piraccini E, Bartolini A, Agnoletti V, Corso R, Gambale G, Vicini C. Am J Emerg Med 2010; 28(7): 840-41

This case report describes the successful use of an i-gel® for a 24-year-old ENT patient in a Columbian hospital. An initial attempt at direct laryngoscopy failed because of a lack of the necessary tools; a size two Miller blade was the only adult blade available. A size three i-gel® was subsequently inserted and immediately established airway patency to facilitate intubation.