i-gel® from Intersurgical: clinical evidence listing

A comprehensive list of all known published clinical evidence on the device

Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) – A human cadaver pilot study

Piegeler T, Roessler B, Goliasch G, Fischer H, Schlaepfer M, Lang S, Ruetzler K. Resuscitation 2016 May;102:70-4

Randomised human cadaver study comparing Laryngeal Tube, EasyTube, LMA Classic, i-gel, ETI and BVM effect on protection against regurgitation and aspiration during CPR. Five minutes of CPR was administered according to 2010 European Resuscitation Council Guidelines. Aspiration was detected in two out of five cadavers with i-gel, while none were recorded when using ETI. Study provides experimental evidence that ETI offers superior protection during CPR.

Link to abstract

Airway management during cardiopulmonary resuscitation

Bernhard M, Benger JR. Curr Opin Crit Care. 2015 Jun;21(3):183-7

An evaluation of latest scientific evidence regarding airway management during in- and out-of-hospital CPR.

Link to abstract

Performance of intubation with 4 different airway devices by unskilled rescuers: manikin study

Lee DW, Kang MJ, Kim YH, Lee JH, Cho KW, Kim YW, Cho JH, Kim YS, Hong CK, Hwang SY. Am J Emerg Med. 2015 May;33(5):691-6

LMA Classic, i-gel, PENTAX Airway Scope and Macintosh laryngoscope were all tested, with time to ventilation, intubation success rate and difficulty of intubation measured. Authors conclude that intubation with i-gel was faster and easier.

Link to abstract

Introduction of the I-gel supraglottic airway device for prehospital airway management in a UK ambulance service.

Duckett J, Fell P, Han K, Kimber C, Taylor C. Emerg Med J. 2014 Jun;31(6):505-7

Clinical review of the advanced airway management techniques within the North East Ambulance Service in the UK. i-gel a popular choice for airway management during prehospital cardiopulmonary resuscitation, giving higher successful insertion rates than endotracheal tube. Authors conclude that they anticipate i-gel will be the first choice device for use in prehospital cardiac arrest.

Link to abstract

Shift of the i-gel position after chest compression: comparison of fixation methods using Durapore tape, Multipore tape, or a fixation strap

Seno H, Komasawa N, Fujiwara S, Miyazaki S, Tatsumi S, Sawai T, Minami T. Masui. 2014 May;63(5):590-3

Manikin study to investigate effectiveness of three fixation methods on an automated chest compressor. Fixation strap may prove useful in stabilising i-gel insertion in this scenario.

Link to abstract