i-gel® from Intersurgical: clinical evidence listing

A comprehensive list of all known published clinical evidence on the device

Tracheal intubation with a camera embedded in the tube tip (VivasightTM)

Huitink JM, Koopman EM, Bouwman RA, Craenen A, Verwoert M, Krage R, Visser IE, Erwteman M, van Groeningen D, Tijink R and Schauer A. Anaesthesia. 2013 Jan;68(1):74-8

Study on tracheal intubation in manikins and patients with a camera embedded in the tip of the tracheal tube Vivasight™ pre-loaded in a size 5 i-gel®. All attempted intubations were successful, with a mean time of 1.4 seconds, and was faster when compared to intubation via LMA®.

Link to abstract.

 

The quality of cardiopulmonary resuscitation using supraglottic airways and intraosseous devices: a simulation trial

Reiter DA, Strother CG, Weingart SD. Resuscitation 2013; 84(1): 93-7

Emergency Medicine residents split into teams took part in two simulated ventricular fibrillation cardiac arrests using a high fidelity simulator, testing whether use of a laryngeal mask airway improved resuscitation results. Time to airway placement, duration and success rate of airway placement and percent hands off time were among results measured. Authors conclude that use of a laryngeal mask and an IO device led to ‘significantly faster establishment of an airway’

Abstract

Supraglottic Airway Device preference and insertion speed in F1 doctors

Adlam M, Purnell D. Resuscitation 2012; 83(5): e129

Twenty-one Foundation Year One Trainees were asked to attempt to ventilate a manikin with either an LMA or i-gel®, of their own choosing. Results showed 71% chose to use an LMA, although on reflection 95% preferred the i-gel®. Speed of insertion was faster with i-gel®. Study supports use of i-gel® on resus trolleys for use by non-airway trained doctors.

Abstract text

Insertion of six different supraglottic airway devices whilst wearing chemical, biological, radiation, nuclear-personal protective equipment: a manikin study

Castle N, Pillay Y, Spencer N. Anaesthesia 2011; 66(11): 983-8

Six different supraglottic airway devices, including i-gel®, were tested by 58 paramedics for speed and ease of insertion in a manikin, whilst wearing either a standard uniform or chemical, biological, radiation, nuclear-person protective equipment (CBRN-PPE). During the latter test, i-gel® was the fastest of the six to insert with a mean insertion time of 19 seconds. Overall, the wearing of CBRN-PPE has a detrimental effect on insertion time of supraglottic airways.

Link to abstract.

 

 

 

Hands-off time during insertion of six airway devices during cardiopulmonary resuscitation: A randomised manikin trial

Ruetzler K, Gruber C, Nabecker S, Wohlfarth P, Priemayr A, Frass M, Kimberger O, Sessler D, Roessler B. Resuscitation 2011; 82(8): 1060-1063

After an audio-visual lecture and practical demonstration, 40 voluntary emergency medical technicians with limited airway management experience were recruited to perform airway management with six devices, including the i-gel®, during sustained compressions on manikins. Hands-off time was significantly longer when inserting a traditional endotracheal tube, whereas the supraglottic devices were inserted successfully on each occasion.

Link to abstract.