Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel® in a manikin

De Lloyd L, Hodzovic I, Voisey S, Wilkes AR, Latto IP. Anaesthesia 2010; 65(1): 36-43

This randomised crossover study compared the cLMA® to the i-gel® during endotracheal intubation of a manikin. 32 anaesthetists took part in the study. For each device, two intubations took place with the tracheal tube directly over the fibrescope and two used an Aintree Intubation Catheter. Intubation took significantly less time with the i-gel® using both methods. Five oesophageal intubations occurred with the cLMA. Anaesthetists stated a preference for the i-gel® due to the ease of use. The authors conclude that the i-gel® is a more appropriate choice for intubation than the cLMA.

Link to abstract.

 

A comparison of the i-gel® supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study

Michalek P, Donaldson W, Graham C, Hinds JD. Resuscitation 2010; 81(1): 74-77

In this study 25 anaesthetists carried out blind and fibreoptic intubations through the ILMA® and i-gel® devices. The study took place with three different airway training manikins. There was no difference in the success rate of fibreoptic intubations between the two airways. During blind intubation, the i-gel® was significantly less successful. The i-gel® is therefore recommended for fibreoptic intubation only.

Link to abstract.

2009 in review

Nolan J P, Soar J, Parr M J A, Perkins G D. Resuscitation 2010; 81(1): 1-4

Focus on the key studies published in Resuscitation in 2009, including cardiac arrest prevention, basic life support and CPR quality

Abstract text

Randomised crossover comparison between the i-gel® and the LMA Unique® in anaesthetised, paralysed adults

Uppal V, Gangaiah S, Fletcher G, Kinsella J. Br J Anaesth 2009; 103(6): 882-885

In this study, the i-gel® and LMA Unique® were both used in 39 patients. Leak pressure, insertion attempts, number of airway manipulations and leak volumes were similar for both devices. Insertion time was significantly less for the i-gel® at 12.2s compared to 15.2s for the LMA Unique®. It can be concluded that the i-gel® is a reasonable alternative to the LMA Unique® during controlled ventilation.

Link to abstract.

 

 

Airway management for out-of-hospital cardiac arrest - more data required

Nolan JP, Lockey D. Resuscitation 2009; 80(12): 1333-1334

This editorial discusses the options that are available for airway management when cardiac arrest occurs outside a hospital environment. It is stated that supraglottic airways are easier to insert than endotracheal tubes and have the added benefit of allowing chest compressions to continue while they are inserted. The article references i-gel® studies with both positive and negative outcomes. Overall, insertion time was quicker but ventilation was sometimes found to be inadequate. One study showed that the i-gel® had a higher leak pressure than the cLMA, however a German study found that the i-gel® produced a tight seal at 20cm H2O in only around half of the patients involved. Most of the available i-gel® data comes from small studies. Randomised controlled trials are needed to confirm the performance of the i-gel® and other supraglottic airways during CPR.

Link to abstract.