The use of i-gel® extraglottic airway during percutaneous dilatational tracheostomy: a case series

Corso RM, Piraccini E, Agnoletti V, Baccanelli M, Coffa A, Gambale G. Minerva Anaestesiol 2011; 77(8): 852-3

The i-gel® was used in eight patients for tracheostomy. Patients were extubated and the ET tube was replaced with the i-gel®. A percutaneous tracheostomy kit was then advanced to the second tracheal ring and the procedure was performed. Arterial pressure, PaO2/FiO2, minute ventilation and airway pressure were measured before, during and after tracheostomy. There were no significant differences in ventilatory and haemodynamic parameters. Use of the i-gel® was successful in seven of eight patients. The i-gel® provided better views of the glottis compared to the cLMA and ventilation was comparable to the ET tube. Large trials must take place to determine whether a one in eight failure rate remains.